Flo - background
Products

Flo

Designed for Food Packaging and Inertisation in Chemical, Thermal and Biological Treatments

GAS TYPE
nitrogen

PURITY
97% - 99,999%

CONFIGURATION
-

Request information
Flo - image
Features
Models
Technical specifications
Applications
Download
  • Purity analyser and pressure regulator:
    fitted as standard to allow real-time monitoring of the
    purity of the nitrogen supplied.
  • digital control system:
    that can be interfaced with company IT systems
    (e.g. plc or scada).
  • single nitrogen storage tank:
    for the operation and storage of the nitrogen
    produced, avoiding the buffer tank.
  • energy saving mode:
    if the nitrogen used is less than the amount produced,
    the generator automatically goes into stand-by mode,
    thus allowing energy savings.
  • E941 food purity:
    option of different calibrations in order to meet
    specific customer needs.
  • continuous monitoring of compressed air quality:
    a humidity and oil particle analyser mounted on
    the suction line prevents impurities from passing
    through, which could compromise the operation of the
    generator and the quality of the gas produced.
  • Flo 1
  • Flo 2
  • Flo 3
  • Flo 4

MODELS

Outgoing nitrogen flow* [Nm3/h]

Purity

99,999%

99,99%

99,9%

99,5%

99%

98%

97%

N2 FLO1

0,2

0,4

0,9

1,5

2

2,4

2,8

N2 FLO2

0,5

0,8

1,8

2,9

3,6

4,6

5,3

N2 FLO3

0,7

1,2

2,6

4,3

5,3

6,7

7,8

N2 FLO4

1

1,7

3,7

5,8

7,2

9,1

10,6

Air/N2 Ratio

6,45

4,80

3,70

2,80

2,65

2,50

2,40

* The flow capacity refers to inlet air nominal conditions: pressure of 8,5 bar, CMS temperature of 20 °C. If the inlet air pressure is different, apply the correction factors reported below.

 

TECHNOLOGIES EMPLOY PSA Claind
INLET AIR SPECIFICATIONS Air pressure : min 6,5 / max 13 bar
Quality: dry, clean, exhalation free. The inlet air must meet the specifications ISO 8573-1, class quality 1.4.1
NITROGEN OUTLET PRESSURE Given the pressure P of the inlet air, the pressure of the nitrogen generated is 1 ÷ 2.5 bar lower than P, depending on the flow rate of nitrogen supplied
MOISTURE CONTENT AT OUTLET -50°C Dew Point ATP
ELETTRICAL SUPPLY 230 Vac ± 10% 50 Hz 115 Vac ± 10% 60 Hz
POWER RATING 50 W
INDEX OF PROTECTION IP20
AVERAGE NOISE ? 60 dB (measured at 1 meter from the generator)
OPERATING TEMPERATURE 5 ÷ 40°C
DIMENSIONS Height: 118 cm
Width: 40 cm
Depth: 80 cm
WEIGHT FLO 1: 92 kg
FLO 2: 113 kg
FLO 3: 134 kg
FLO 4: 155 kg

 

  • Food packaging and bottling, in particular of wine, oil, fruit juices and mineral waters
  • Inertisation of Chemical and Biological Processes
  • Thermal treatments
User Manual FLO
User Manual FLO Download
Product Sheet FLO
Product Sheet FLO Download

Flo

Designed for Food Packaging and Inertisation in Chemical, Thermal and Biological Treatments

Flo

Discover all after-sales services

At Claind we are committed to a high standard of service and to promptly responding to all of our customers' requests.

Discover all after-sales services
Documentation download

Richiesta avvenuta correttamente!

Ti ringraziamo per il tuo interesse.
Riceverà presto una mail con i link per i file richiesto!

Fill the form to receive the download link for the required material
Enter a valid e-mail addressAn error has occurred. Please try again later.

Fields marked with an asterisk (*) are mandatory

Newsletter

Subscribe to our Newsletter.

Subscribe