MODELS |
Outgoing nitrogen flow* [Nm3/h] |
||||||
Purity |
99,999% |
99,99% |
99,9% |
99,5% |
99% |
98% |
97% |
N2 PICO3 |
1,5 |
2,5 |
5,4 |
8,6 |
10,4 |
13,8 |
16,1 |
N2 PICO4 |
2 |
3,3 |
6,9 |
11,5 |
15 |
18,4 |
20.7 |
N2 PICO5 |
2,3 |
4,0 |
9,2 |
14,4 |
18,4 |
23 |
26,5 |
N2 PICO6 |
3,5 |
5,0 |
10,4 |
17,3 |
21,9 |
27,9 |
31,1 |
Air/N2 Ratio |
6,45 |
4,80 |
3,70 |
2,80 |
2,65 |
2,50 |
2,40 |
* The flow capacity refers to inlet air nominal conditions: pressure of 8,5 bar, CMS temperature of 20 °C. If the inlet air pressure is different, apply the correction factors reported below.
TECHNOLOGIES EMPLOY | PSA CLAIND |
INLET AIR SPECIFICATIONS | Air pressure : min 6,5 / max 13 bar Quality: dry, clean, exhalation free. The inlet air must meet the specifications ISO 8573-1, class quality 1.4.1. |
NITROGEN OUTLET PRESSURE | Given the pressure P of the inlet air, the pressure of the nitrogen generated is 1 ÷ 2.5 bar lower than P, depending on the flow rate of nitrogen supplied |
MOISTURE CONTENT AT OUTLET | -50°C Dew Point ATP |
ELETTRICAL SUPPLY | 230 Vac ± 10% 50 Hz 115 Vac ± 10% 60 Hz |
POWER RATING | 50 W |
INDEX OF PROTECTION | IP20 |
AVERAGE NOISE | ≤ 60 dB (measured at 1 meter from the generator) |
OPERATING TEMPERATURE | 5 ÷ 40°C |
DIMENSIONS | Height: 138 cm Width: 40 cm Depth: 130 cm |
WEIGHT | PICO 3: 230 kg PICO 4: 270 kg PICO 5: 310 kg PICO 6: 350 kg |
Entwickelt für Food Packging und die Inertisierung bei chemischen, thermischen und biologischen Behandlungen
Wir bei Claind verpflichten uns zu einem hohen Servicestandard und zur zeitnahen Beantwortung aller Kundenanfragen.