Discover the Claind4You IoT platform from which you can independently manage and control your Claind generators.
MODELS |
Outgoing nitrogen flow* [Nm3/h] |
||||||
Purity |
99,999% |
99,99% |
99,9% |
99,5% |
99% |
98% |
97% |
N2 FLO1 |
0,2 |
0,4 |
0,9 |
1,5 |
2 |
2,4 |
2,8 |
N2 FLO2 |
0,5 |
0,8 |
1,8 |
2,9 |
3,6 |
4,6 |
5,3 |
N2 FLO3 |
0,7 |
1,2 |
2,6 |
4,3 |
5,3 |
6,7 |
7,8 |
N2 FLO4 |
1 |
1,7 |
3,7 |
5,8 |
7,2 |
9,1 |
10,6 |
Air/N2 Ratio |
6,45 |
4,80 |
3,70 |
2,80 |
2,65 |
2,50 |
2,40 |
* The flow capacity refers to inlet air nominal conditions: pressure of 8,5 bar, CMS temperature of 20 °C. If the inlet air pressure is different, apply the correction factors reported below.
TECHNOLOGIES EMPLOY | PSA Claind |
INLET AIR SPECIFICATIONS | Air pressure : min 6,5 / max 13 bar Quality: dry, clean, exhalation free. The inlet air must meet the specifications ISO 8573-1, class quality 1.4.1 |
NITROGEN OUTLET PRESSURE | Given the pressure P of the inlet air, the pressure of the nitrogen generated is 1 ÷ 2.5 bar lower than P, depending on the flow rate of nitrogen supplied |
MOISTURE CONTENT AT OUTLET | -50°C Dew Point ATP |
ELETTRICAL SUPPLY | 230 Vac ± 10% 50 Hz 115 Vac ± 10% 60 Hz |
POWER RATING | 50 W |
INDEX OF PROTECTION | IP20 |
AVERAGE NOISE | ? 60 dB (measured at 1 meter from the generator) |
OPERATING TEMPERATURE | 5 ÷ 40°C |
DIMENSIONS | Height: 118 cm Width: 40 cm Depth: 80 cm |
WEIGHT | FLO 1: 92 kg FLO 2: 113 kg FLO 3: 134 kg FLO 4: 155 kg |
Designed for Food Packaging and Inertisation in Chemical, Thermal and Biological Treatments
At Claind we are committed to a high standard of service and to promptly responding to all of our customers' requests.